TRAFFIC LIGHT UPS

Suitable for outdoor weather environment (-37°C to +75ºC)
Backs up power to traffic control and signal equipment
Fits in all types of traffic enclosures or can be mounted in an electrical service or custom pedestal
Low harmonic AC sinewave output
Fully programmable AC threshold voltages
Transient voltage protection from damaging line spikes external connections are front panel accessible
Six fully programmable dry contacts - provides greater control of system components and functions
   backlit LCD display and 2 LEDs indicator
Remote access via RS-232, USB, SNMP (option) and TCP/IP (option)
Time / date stamp of events and alarms - up to 100 events with download and print capability
Temperature - compensated charging maximizes battery life in harsh, outside environments

   

SPECIFICATION

MODEL    TRL-2000
INPUT  Nominal Voltage 120VAC+/-25%
  Transfer Voltages Values programmable within 120VAC +/- 25% range 
  (Line to Battery) *1 (Default values 100 VAC = Low Line, 130 VAC = High Line) 
  Re Transfer Voltages  Values programmable within 120VAC +/- 25% range 
  (Battery to Line) (Default Hysterisis 105 VAC = Low Line, 125 VAC = High Hysterisis) 
  Boost Range *2   Values programmable within 120VAC - 20 % range with a 15% step 
    (Default values DISABLE)
  Buck Range *3 Values programmable within 120VAC - 20 % range with a 15% step
     (Default values DISABLE)
  Nominal Frequency : 60 Hertz
  Frequency Fail Detection Values programmable within 60 +/- 5 Hertz range
  (Transfer from Line to Battery) *4  (Default values <57 and >63 Hertz)
  Frequency Fail Recover Values programmable within 60 +/- 4 Hertz range 
  (Retransfer to Line from Battery)  (Default values 60 +/-1 % Hertz) 
  Current  30 Amps max
  Optional Source  AC Generator of size 1.5 x Load, with voltage and Frequency Variations with slower detection and less sensitivity DC Generator for continuous Inverter operation 
  Efficiency  >95% in the Line Mode at 1.0 PF Full Load, with fully charged batteries
  Connection  One 3 position Terminal Block
  Protection  30 Amps Circuit Breaker
  Surge Protection ANSI / IEEE C 62.41, Category A (2KV), 1.2 x 50 usec. Combination type 50 pulses min. @ 10 sec. Interval
OUTPUT  Power (continuous rating)  2000 VA/1500 Watts (below +65 deg. C), Above +65 deg. C 
unit derated to 2000 VA/ 1400 Watts respectively
  Power factor 0.75
  Voltage  120 +/- 5% VAC, Battery Mode 120 VAC +/-25%, Line Mode (depend on item *1) 120 +/- 10% VAC, Buck / Boost Mode (depend on item *2 and *3)
  Voltage THD
(Total Harmonics Distortion)
< 5%, UPS on battery, 100% resistive load
  Frequency Line Mode 60 +/- 3 Hertz (depend on item *4)
  Frequency Battery Mode 60 +/- 0.5 Hertz
  Current  25 Amps max
  Connection  Dual 3 position Terminal Block
  Protection  30 Amps Circuit Breaker and Fast electronic shutdown
  Dielectric  1240 VAC / 1340 VDC for 1 minute, L-G / N-G
  Transfer Time (Line to Battery) 6 ms, typically
  ReTransfer Time (Battery to Line)  6ms, after wait time of either 30 or 10 or 3 seconds (programmable)
  Crest factor, Current 3:1
  Waveform  Sine Wave 
  Overload  > 110% for 3 min seconds, >150% for 10 seconds, >200% for 1 seconds.
BATTERY  Voltage  48 VDC
  Battery Protection 60 Amps Circuit Breaker with Finger Guard
  Connection  PCM 75A connector
  Efficiency  > 80% in Battery Mode
  Test Jacks One Red and One Black Test Jack (Banana type) sockets to test Battery Voltage
CHARGER  Nominal Voltage 48 VDC
  Current  10 Amps DC, Adjustable
  Temperature Compensation   External, pluggable sensor, 2 Meters long wires, compensation of -3, -4
and -5 mV / deg C / cell over -37 to +50 deg C range, via 3 pin
mat-n lock type socket on the front panel
  Low Battery shutdown 1.75 volt/cell min
  Low Battery Alarm  Value programmable in 0.1 VDC increment over 42 to 50 VDC range for the realy contact at Green Terminal Block
  Charging SHUT-OFF Above 50 degrees C 
ENVIRONMENTAL  Operating Temperature (-) 37 to (+) 75 degrees C 
  Storage Temperature (-) 50 to (+) 80 degrees C 
  Relative Humidity 0 to 95% Non-Condensing
  Altitude  12,000' / 3600 meter, Derate Operating Temperature by 2 deg.
C / 1000 ft. (300m), above 5000 ft. (1530 m)
  Audible Noise < 60 dBA
  Cooling  Forced air with Thermostatically controlled fan
MECHANICAL  Size W x D x H mm  432x280x133
  Mounting  Shelf mount Horizontal or Vertical. 19" or 23" Rack Mount, 
Rack Ears & 10/32 hardware optional
  Weight  < 60 lbs
COMMUNICATION PORT   One RS232C Port with DB9 Female connector, and one USB Port, and one solt for SNMP or TCP/IP card. Which are optically isolated for Monitor, Control and Calibration of UPS via software